The Dupill Group, Inc.  
Home
Products
 
Remote Valve Operators
 
Solenoid Valves
 
process & control valves Process &
Control Valves
 
Special Purpose
Valves
 
3-Way Values
 
4-Way Valves
 
Other Valves
 
Valve Worksheet
 
Valve Actuators Valve Actuators
 
Valve Lapping Tools
 
instrumentation for valve industry Instrumentation & Control Devices
 
Valve Test Equipment Valve Test Equipment
 
Valve Diagnostics Valve Diagnostics
Training
Industrial Valve Repair Valve Repair and Consulting Service
Valve Repair Equipment Rental Valve Repair Equipment Rentals
References
Markets Served
Request a Quote
Career Opportunities
Contact Us
Select a Company to Learn What The Dupill Group Offers

Lars Lap

Delcua for Valve Test Equipment and Training
Velan
Weed Instrument
Valcor
I.A.F.D
Solidstate
Smith Flow Control
Areva Ultracheck RV for Valve Diagnostics
Actuators by RA Hiller

Valcor Valves3 Way Solenoid Valves


These solenoid valves have three pipe connections and two orifices. When one orifice is open, the other is closed and vice versa. They are commonly used to alternately apply pressure to an exhaust pressure from a valve actuator or a single acting cylinder. These valves can be normally closed, normally open or universal.

Submit a Solenoid Valve Application Data Sheet for a proposal.

Valve Specifications:

3- Way Valves
Valcor Valves
Direct Acting 3 Way Valve
Balanced Poppet 3 Way Solenoid Valve
Remote Pilot Assist Solenoid Valve
Direct Acting 3 way Solenoid Valve
Valve Series Number
V70900-98
V70900-65
V70900-99
V100000-249
Type of Operation1
Direct Acting
Balanced Poppet
Remote Pilot Assist
Direct Acting
Operating Modes
N/O, N/C, D, S
N/O, N/C, D, S
N/O, N/C, D, S
Air Actuated
Line Connection
1/8”, 1/4”, 3/8”, 1/2”
1/8”, 1/4”, 3/8”, 1/2”
1/2”, 3/4”, 1”, 2”
1/2”, 3/4”, 1”, 2”
Cv Factor
0.2
0.2 to 1.2
1.2 to 45
2.5 - 5.5
Flow Capacity
Low
Moderate
High
High
Operating Pressure
0 - 150 psig
0 - 150 psig
10 - 150 psig
0 - 150 psig
Operating Temperature
150°F (66°C)
150°F (66°C)
150°F (66°C)
150°F (66°C)
Response Time
30 m-sec
30 m-sec
100 m-sec
200 m-sec
Seat Leakage
ANSI/FCI 70-2
Class 5 or better
Class 5 or better
Class 5 or better
Class 5 or better
Seat Material
Arlon or VespelTM
Arlon or VespelTM
Arlon or VespelTM
Arlon or VespelTM
Body Material
Brass2/Aluminum
Brass2/Aluminum
Brass2/Aluminum
Bronze2
Mounting Attitude3
any
any
any
Vertical/Horizontal
Electrical Connections4
36” leads
36” leads
36” leads
Coil Class
H
H
H
Coil Wattage
10
10
10
Voltages5
AC/DC
AC/DC
AC/DC
NEMA Compliance
4,7
4,7
4,7
IEEE Qualification
323, 344, 382
323, 344, 382
323, 344, 382
323, 344, 382
Qualified Life - Coil
40 years
40 years
40 years
Qualified Life - O-Rings7
10 years
10 years
10 years
5 years
1 3-way valves can be used as 2-way NO/NC by plugging unused port
2 Also available in Stainless Steel
3 Mounting brackets available
4
ECSA/QDC available
5 Standard voltages available 120 VAC, 125 VDC, 48 VDC, Consult factory for special voltages
6 Shown as manifold assembly
7 Typical - Dependent on duty cycle and pre/post LOCA/HELB ambient conditions
Operating Modes: NC - Normally Closed, NO - Normally Open, D - Diverter, S - Selector