We can provide seismically qualified
instrumentation of all types (mechanical, electrical,
electronic) for most nuclear requirements. The seismic
qualification is supported by comprehensive documentation
(qualification plans, procedures, and reports), all
of which are subject to prior customer acceptance.
Reverse
Engineering
When necessary, obsolete instrumentation
can be replaced with reverse-engineered equivalents.
These are typically designed to be form, fit, and functionally
equivalent to the original installed components, meeting
or exceeding the performance requirements of the product.
Item Equivalency Evaluations, prepared
in accordance with EPRI NP-6406, are used to document
and evaluate any changes to the original configurations.
In addition, full functional testing and commercial
grade dedication in accordance with EPRI NP-5652 is
performed based on the safety-related function of the
instrument.